Conference150th anniversary of the Metre Convention — From Units to the Universe
Year2025
LocationPalais des congrès de Versailles, Versailles, France
PublisherBureau International des Poids et Mesures (BIPM)
LanguageEN
ABSTRACT
Micro-cantilever probes used in Atomic Force Microscopy (AFM) have been widely employed for characterizing the surface topography of nano- and micro-structures as well as for testing material properties. As the demand for applications in fundamental research grows, measurement technologies utilizing micro-cantilever probes has expanded to include mass measurement of cell growth, analysis of chemical properties and light pressure measurement. All the applications described utilize the micro-cantilever stiffness in the normal direction, and the uncertainty in calibrating this stiffness directly impacts the accuracy of the measurements. Due to the imprecision of micromachining technology in manufacturing micro-cantilevers, the nominal stiffness of these produced micro-cantilevers varies widely. The results obtained from micro-cantilever measurements cannot be linked to the SI standard. Therefore, it is essential to calibrate the normal stiffness of the micro-cantilever to enhance measurement accuracy in various applications. The National Institute of Metrology (NIM) has developed an electrostatic force balance (EFB) apparatus for measuring force at nano- and micro-newton levels. The EFB can measure forces ranging from 10 μN to 100 μN with a relative uncertainty of 5×10-5 (k=1), and from 1 μN to 5 μN with a relative uncertainty of 5×10-4 (k=1). The force generated by the EFB can also serve as a force source in the contact method for calibrating stiffness. Compared to other force sources like magnetic balances or reference cantilevers, the traceable force generated from the EFB at the nano-newton level can effectively calibrate micro-cantilevers with high sensitivity, which typically have a stiffness of about 0.01 N/m. The latest results from NIM indicate that the stiffness of a micro-cantilever with a nominal stiffness of 0.05 N/m can be accurately determined using the EFB apparatus. In the future, an optical method for accurately adjusting the displacement and posture of the micro-cantilever will be developed to reduce the uncertainty components of the orientation introduced in the stiffness calibration. The stiffness calibration method effectively improves traceability for micro-cantilever measurements of small mass or force at the picoNewton level.
CITE THIS POSTER
Include:
ZHANG, K., BAI, Y., & ZHANG, Z.. (2025). Calibration of the Micro-Cantilever Stiffness Using the EFB Apparatus. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/QFFX3352
ZHANG, KAI, et al.. “Calibration of the Micro-Cantilever Stiffness Using the EFB Apparatus.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/QFFX3352
ZHANG, KAI, YANG BAI, ZHIMIN ZHANG. 2025. “Calibration of the Micro-Cantilever Stiffness Using the EFB Apparatus.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/QFFX3352
@inproceedings{zhang2025calibration_of_the_m,
author = {ZHANG, KAI and BAI, YANG and ZHANG, ZHIMIN},
title = {Calibration of the Micro-Cantilever Stiffness Using the EFB Apparatus},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/QFFX3352},
url = {https://thebipm150.org/poster-page/10euh7b},
}
TY - CONF
AU - ZHANG, KAI
AU - BAI, YANG
AU - ZHANG, ZHIMIN
TI - Calibration of the Micro-Cantilever Stiffness Using the EFB Apparatus
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/QFFX3352
UR - https://thebipm150.org/poster-page/10euh7b
ER -