Conference150th anniversary of the Metre Convention — From Units to the Universe
Year2025
LocationPalais des congrès de Versailles, Versailles, France
PublisherBureau International des Poids et Mesures (BIPM)
LanguageEN
ABSTRACT
Certified reference materials (CRMs) are widely used to guarantee accurate and comparable results in chemical analysis. Purity CRMs usually locate at the top of metrological traceability hierarchy, and are prerequisites for solutions and matrix CRMs. Mass balance (MB), and quantitative nuclear magnetic resonance (qNMR) are widely used primary measurement methods for the purity assessment of organic CRMs. In MB, the normalized peak area ignores the difference among different impurities. The response of non-structurally related impurities in chromatography will lead to a big bias. In qNMR, the selection of quantitative hydrogen or other nuclei determines the accuracy of results, because the overlap between the measureand and structurally related impurities may introduce a positive bias for mass fraction. From above all, impurity fingerprint decoding is vitally important for purity assignment in both MB and qNMR.
However, structurally related impurities identification and quantification are significant and challenging work. In CCQM K55.a and K148.a comparisons, numerous trace level impurities were visibly present, but no consensus was reported for their identity. Just as stated in ISO 33407:2024, this can be the most critical and challenging effort of CRM characterization due to the large number of possible impurity structures.
Here, a new strategy combining liquid chromatography-high resolution mass spectrometry (LC-HRMS) and de novo identification tool (SIRIUS) was developed for the identification of the structurally related impurities. HRMS was adopted to acquire the MS and MS/MS spectra of impurities after chromatography separation. Then, isotope pattern analysis was used for MS data to find molecular formula, and fragmentation tree was used for MS/MS data to elucidate chemical structure. Algorithms including Bayesian analysis and maximum a posteriori estimation worked to score structure candidates. Simultaneously, the main component worked as an anchor for structure elucidation and impurity confirmation by the shared neutral loss and fragmented ions.
By this strategy, 18, 4, 3, 26, 28 and 28 impurities were elucidated in thiacloprid, thiamethoxam and dinotefuran, clothianidin, imidacloprid and acetamiprid materials respectively. These impurities were from intermediate residue, side reaction or degradation products. Among them, a few impurities were further verified with chemical standards but most impurities were reported for the first time even didn’t have CAS numbers. This work provides a new perspective and instructive method for impurity identification in purity assignment in MB and qNMR.
Inspired by the success of this technique, we are studying the purity materials of CCQM K55.a and K148.a comparisons and hope to elucidate the unidentified impurities.
ORCID: Xianjiang Li (0000-0003-0310-0376)
Mengling Tu (0000-0002-2077-8528)
CITE THIS POSTER
Include:
Li, X., & Tu, M.. (2025). Impurity fingerprint decoding: the common foundation for MB and qNMR. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/JBJB9476
Li, Xianjiang, and Mengling Tu. “Impurity fingerprint decoding: the common foundation for MB and qNMR.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/JBJB9476
Li, Xianjiang, Mengling Tu. 2025. “Impurity fingerprint decoding: the common foundation for MB and qNMR.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/JBJB9476
@inproceedings{li2025impurity_fingerprint,
author = {Li, Xianjiang and Tu, Mengling},
title = {Impurity fingerprint decoding: the common foundation for MB and qNMR},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/JBJB9476},
url = {https://thebipm150.org/poster-page/10euhd3},
}
TY - CONF
AU - Li, Xianjiang
AU - Tu, Mengling
TI - Impurity fingerprint decoding: the common foundation for MB and qNMR
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/JBJB9476
UR - https://thebipm150.org/poster-page/10euhd3
ER -