Conference150th anniversary of the Metre Convention — From Units to the Universe
Year2025
LocationPalais des congrès de Versailles, Versailles, France
PublisherBureau International des Poids et Mesures (BIPM)
LanguageEN
ABSTRACT
Photonics as a key enabling technology is driving the technological development in sensing, health, industry and environment. The development trend moves towards miniaturised and integrated measurement systems. This puts pressure on the metrology community; How can we assure measurement accuracy and SI traceability in an integrated, miniaturised or remote measurement system?
Through European metrology projects, improved room temperature self-calibration technology has been developed for silicon photodiodes linking their spectral response to the fundamental constants defined in the SI system of units. In contradiction to the cryogenic electrical substitution radiometer (CESR) the methodology exploits the quantum nature of radiation and the fact that each photon generates one electron-hole pair in the photodiode; an ideal process described by the fundamental constants e, h and the radiation frequency. To extract the true responsivity, the projects developed techniques to reduce and quantify the reflectance and internal photodiode losses. The work focused on developing virtually loss free photodiodes and three independent methods to quantify their residual losses.
The first method applies simulation models fitted to measured charge-carrier lifetime measurements quantifying the expected losses of photodiodes manufactured with the passivation layer deposition recipe. This technique turned out to be extremely useful when developing the virtually loss free photodiode as the method is very quick and don’t require a costly, time-consuming manufacturing and characterisation of photodiodes. Multiple generations of detectors could be tested in a short time which led to the development of photodiodes with less than 10 ppm relative internal losses.
The second method of self-calibration consists of measuring the photocurrent as a function of bias voltage at different power levels and fits a 3D simulation model to the measured photocurrent curves. From these measurements the photodiode defining parameters can be extracted and the responsivity over the full spectral range can be predicted from the measurements done at one wavelength only. Not only does this approach simplify the traceability, but it also shows that the photodiodes can be calibrated in their own application without the need to take them to the laboratory, making them suitable as a built-in reference in integrated miniaturised measurement set-ups. It provides a room temperature standard with similar or improved performance as compared to the CESR.
The third self-calibration method is a purely experimental technique realised as the dual-mode detector, where photocurrent and electrical substitution is combined on a photodiode chip. Here room temperature measurements with relative uncertainties of 150 ppm (k=1) are limited by systematic effects.
With the improved photodiodes and metrology exploiting digital simulation models we have developed an “NMI-on-a-chip” technology that is suitable for miniaturised, integrated measurement systems. SI traceability is ensured by the intrinsic reference photodiodes for use in, e.g., health diagnostics, quantum technology, environmental measurements or the industrial technology development of photonic integrated circuits. Therefore, our work demonstrates a path forward to meet the challenges identified by industrial and metrology organisations like Photonics21 and CIPM on integrated metrology.
CITE THIS POSTER
Include:
Gran, J., Solheim, J. H., Tran, T., Koybasi, O., Povoli, M., Nordseth, , Bardalen, E., Rajteri, M., Pepe, C., Ikonen, E., Dönsberg, T., Porrovecchio, G., & Werner, L.. (2025). Self-calibrating photodiodes and new measurement techniques will provide traceability in previously inaccessible areas in rapid development. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/TMSU6669
Gran, Jarle, et al.. “Self-calibrating photodiodes and new measurement techniques will provide traceability in previously inaccessible areas in rapid development.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/TMSU6669
Gran, Jarle, et al.. 2025. “Self-calibrating photodiodes and new measurement techniques will provide traceability in previously inaccessible areas in rapid development.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/TMSU6669
@inproceedings{gran2025selfcalibrating_pho,
author = {Gran, Jarle and Solheim, Johanne Heitmann and Tran, Trinh and Koybasi, Ozhan and Povoli, Marco and Nordseth, Ørnulf and Bardalen, Eivind and Rajteri, Mauro and Pepe, Carlo and Ikonen, Erkki and Dönsberg, Timo and Porrovecchio, Geiland and Werner, Lutz},
title = {Self-calibrating photodiodes and new measurement techniques will provide traceability in previously inaccessible areas in rapid development},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/TMSU6669},
url = {https://thebipm150.org/poster-page/10euhie},
}
TY - CONF
AU - Gran, Jarle
AU - Solheim, Johanne Heitmann
AU - Tran, Trinh
AU - Koybasi, Ozhan
AU - Povoli, Marco
AU - Nordseth, Ørnulf
AU - Bardalen, Eivind
AU - Rajteri, Mauro
AU - Pepe, Carlo
AU - Ikonen, Erkki
AU - Dönsberg, Timo
AU - Porrovecchio, Geiland
AU - Werner, Lutz
TI - Self-calibrating photodiodes and new measurement techniques will provide traceability in previously inaccessible areas in rapid development
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/TMSU6669
UR - https://thebipm150.org/poster-page/10euhie
ER -