Conference150th anniversary of the Metre Convention — From Units to the Universe
Year2025
LocationPalais des congrès de Versailles, Versailles, France
PublisherBureau International des Poids et Mesures (BIPM)
LanguageEN
ABSTRACT
In the context of ocean deoxygenation and increase of hypoxia events in response to climate change and anthropogenic releases, many questions exist about the analytical performances of optodes and electrodes used to measure dissolved oxygen in high gradient zones (lakes, estuaries, Oxygen Minimum Zones in open ocean). In those gradients, i.e. between fully oxygenated environments and hypoxic, or even anoxic, environments, comparing the performance of commercial sensors has become essential to harmonize their implementation and estimate the overall in situ measurement uncertainty.
Tests were carried out under the AQUAREF (French National Reference Laboratory in support of aquatic environment monitoring) umbrella on Lake Pavin (Massif central, France) in June 2024 with optodes used by 10 laboratories for measurements in lakes, groundwater, rivers, estuaries, coastal and oceanic waters. Lake Pavin is a meromictic lake, which presents in early summer three zones of interest for dissolved oxygen measurements:
1. An oxygenated surface layer between 0 and 25 m (at the top of the mixolimnion) in which is observed a peak of supersaturated oxygen concentrations corresponding related to the photosynthetic activity of highly productive phytoplankton;
2. A transition zone between 50 and 60 m presenting a strong negative gradient (oxycline within the mesolimnion layer);
3. An anoxic zone between 60 and 90 m depth, which corresponds to the monimolimnion.
Several dissolved oxygen profiles were carried out using a frame on which were mounted 22 portable meter instruments (multiparameter or dissolved oxygen only) from various manufacturers, including 8 identical ones, in order to:
- Quantify measurement uncertainties in gradient zones,
- Identify and quantify the most significant interferences in terms of bias,
- Estimate the detection limit in anoxic zones,
- Evaluate the minimum stabilization time in the gradient zones and in the anoxic zone,
- Compare measurements collected during downcast and upcast,
- Evaluate the influence of the downcast/upcast speed and of stop duration at vari-ous depths.
The profiles were carried out with different downcast/upcast speeds and with various stop durations at depths of interest. Continuous measurements were also taken over-night at a fixed point in the anoxic layer. Water samples were collected using a Niskin bottle for dissolved oxygen cross-calibration using the Winkler reference method.
Two statistical treatments were implemented to estimate the standard deviation of re-producibility between optodes (EN ISO 5725-2 standard and algorithm A of the EN ISO 13528 standard). Furthermore, an estimation of the overall measurement uncertainty was carried out for the 8 identical optodes using the RANOVA4 software.
The results showed significantly better performances during upcast, with slow speed and when stops of 5 min are carried out at depths of interest. These results will enable us to propose recommendations (1) for choosing optodes according to measurement objectives and expected dissolved oxygen concentration ranges, and (2) for carrying out profiles un-der conditions that limit the measurement uncertainties to monitor with confidence trends and extreme events in changing aquatic environments.
CITE THIS POSTER
Include:
DANIEL, A., GUIGUES, N., BILLARD, H., CARADEC, F., GAL, F., JEZEQUEL, D., LEFEVRE, D., LE JEUNE, A., PAULMIER, A., PERRIERE, F., QUETIN, P., RAUTUREAU, C., RETHO, M., & VIOLIER, E.. (2025). Assessment of optodes analytical performances in high dissolved oxygen gradient zones. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/AOXQ0980
DANIEL, Anne, et al.. “Assessment of optodes analytical performances in high dissolved oxygen gradient zones.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/AOXQ0980
DANIEL, Anne, et al.. 2025. “Assessment of optodes analytical performances in high dissolved oxygen gradient zones.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/AOXQ0980
@inproceedings{daniel2025assessment_of_optode,
author = {DANIEL, Anne and GUIGUES, Nathalie and BILLARD, Hermine and CARADEC, Florian and GAL, Frédérick and JEZEQUEL, Didier and LEFEVRE, Dominique and LE JEUNE, Anne-Hélène and PAULMIER, Aurélien and PERRIERE, Fanny and QUETIN, Philippe and RAUTUREAU, Clément and RETHO, Michael and VIOLIER, Eric},
title = {Assessment of optodes analytical performances in high dissolved oxygen gradient zones},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/AOXQ0980},
url = {https://thebipm150.org/poster-page/10euhmd},
}
TY - CONF
AU - DANIEL, Anne
AU - GUIGUES, Nathalie
AU - BILLARD, Hermine
AU - CARADEC, Florian
AU - GAL, Frédérick
AU - JEZEQUEL, Didier
AU - LEFEVRE, Dominique
AU - LE JEUNE, Anne-Hélène
AU - PAULMIER, Aurélien
AU - PERRIERE, Fanny
AU - QUETIN, Philippe
AU - RAUTUREAU, Clément
AU - RETHO, Michael
AU - VIOLIER, Eric
TI - Assessment of optodes analytical performances in high dissolved oxygen gradient zones
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/AOXQ0980
UR - https://thebipm150.org/poster-page/10euhmd
ER -