ABSTRACT
One central building block for the revision of the SI base units kilogram and mole in 2019 and their ongoing realization and dissemination via the X-ray crystal density (XRCD) method is the metrological determination of the molar mass M and isotopic composition x(i^Si) of ultra-pure silicon crystals highly enriched in 28Si with lowest associated uncertainty. The International Avogadro Coordination and PTB produced six crystals (x_rel(28Si) > 99.99%) each providing two spheres. A pool of twelve spheres exists, representing primary standards for key comparisons and dissemination purposes. As part of the XRCD method, high resolution isotope ratio mass spectrometry for the measurement of the isotopic composition has been continuously improved using the principle of the virtual-element isotope dilution mass spectrometry (VE-IDMS) together with an ab-initio experimental determination of calibration factors for isotope ratios – which was the first successful application of this procedure in metrology in chemistry. With these tools, the uncertainty associated with the molar mass has been reduced by more than two orders of magnitude over one decade down to u_rel(M) 0.999 97 mol/mol) as well as strongly depleted in 30Si (x(30Si) 170 mol/mol which is very difficult to measure along with sufficiently small associated uncertainties. An improved protocol using highly sensitive detection modes (e.g. high ohmic resistors in the feedback loop of the detector amplifiers) will be applied.
In parallel, a new measurement protocol using laser ablation (LA-) MC-ICP-MS has been developed and applied for the first time to an ultra-pure Si crystal with almost natural isotopic composition in combination with a respective dissolved sample used in the XRCD method. Absolute isotope ratio measurements of this material using LA-MC-ICP-MS qualifies it as a kind of reference material for fast and accurate calibration of any pure Si material needed not only in basic metrology but also for e.g. semiconductor applications. The material and time saving adoption of LA-MC-ICP-MS to highly enriched Si crystals is a topic of planned future research in the context of XRCD.
The validated experience and knowledge of the measurement of the isotopic composition of Si crystals highly enriched in 28Si can serve as a basis for an Si traceable characterization and calibration of new quantum materials (qubits) which might be produced in a larger scale, thus the reported experiences of measurements of highly enriched Si can be regarded as a basic fundament for scientific “spin-off” in quantum technological applications.
CITE THIS POSTER
Include:
Pramann, A., & Rienitz, O.. (2025). High resolution isotope ratio mass spectrometry: From the dissemination of the kilogram and the mole towards supporting the characterization of quantum qubits. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/UMNM5285
Pramann, Axel, and Olaf Rienitz. “High resolution isotope ratio mass spectrometry: From the dissemination of the kilogram and the mole towards supporting the characterization of quantum qubits.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/UMNM5285
Pramann, Axel, Olaf Rienitz. 2025. “High resolution isotope ratio mass spectrometry: From the dissemination of the kilogram and the mole towards supporting the characterization of quantum qubits.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/UMNM5285
@inproceedings{pramann2025high_resolution_isot,
author = {Pramann, Axel and Rienitz, Olaf},
title = {High resolution isotope ratio mass spectrometry: From the dissemination of the kilogram and the mole towards supporting the characterization of quantum qubits},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/UMNM5285},
url = {https://thebipm150.org/poster-page/10euht2},
}
TY - CONF
AU - Pramann, Axel
AU - Rienitz, Olaf
TI - High resolution isotope ratio mass spectrometry: From the dissemination of the kilogram and the mole towards supporting the characterization of quantum qubits
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/UMNM5285
UR - https://thebipm150.org/poster-page/10euht2
ER -