Efficient verification of high-power DC charging stations with a PTB Phantom Power Test Setup

AUTHORS
Michael Blaz

Researcher, PTB, Germany

Enrico Mohns

PTB

Christoph Leicht

PTB

Matthias Schmidt

PTB

4
Views
0
Downloads
MEDIA
Download PDF
DETAILS
Theme 5. Energy
Conference 150th anniversary of the Metre Convention — From Units to the Universe
Year 2025
Location Palais des congrès de Versailles, Versailles, France
Publisher Bureau International des Poids et Mesures (BIPM)
Language EN
ABSTRACT
Many participants at the UN Climate Change Conference declared the goal of accelerating the transition to zero-emission vehicles. By 2040, all new cars sold should be emission-free. This target will increase the number of electric vehicles (EV's) and therefore the number of public charging stations (EVCS). The acceptance of this charging infrastructure and thus the acceptance of electromobility itself depends on the reliability of the measured energy that the customer must pay for. The verification of the EVCS metering system is fundamental to reliable metering. When verifying the EVCS, however, the problem arises of testing the charging equipment at any operating point within the operating range. The use of regenerative loads is expensive, but possible in a laboratory environment. This, however, is no longer practicable in the field due to the great effort involved and the lack of a grid connection to feed the energy back into the grid. Also, the use of EV's or passive loads as a load for the EVCS seems to be a solution with limited possibilities in terms of selecting suitable voltages and currents for of measuring points. To avoid these problems, the use of phantom power source is an option.
The phantom power measurement setup that has been used for decades for testing electricity meters is not directly applicable, as no separate voltage and current connections are accessible at the EVCS. The phantom power test setup we propose from PTB side overcomes this difficulty by using two separate current sources to drive the currents through the DC+ and DC- path of the EVCS. Another voltage source is used to generate the potential difference between the DC+ and DC- terminals of the EVCS. With this setup, which is basically able to test up to 1500 V and up to 900 A, it is possible to consider the influence of losses on the measurement that occur between the electricity meter and the connection point to the EV. The connection point to the EV is the energy transfer point at which the charging device must correctly record the energy. To ensure the functionality of this setup, accuracy measurements were carried out with an EVCS using the phantom power setup. These measurements were compared with the results when a regenerative load is used. No significant differences were found between the results of the accuracy measurements. It was also possible to carry out tests with much higher power in the order of hundreds of kilowatts with the phantom power test setup, while its power consumption is just some kilowatts and requires less space than with the regenerative load.
The integration of this test setup and procedure into standardisation will be important for the future, as the charging stations must meet certain requirements to be verified in the field with phantom power. Here national standardisation in Germany as well as in Europe is underway. These standardisation efforts will ensure the interoperability of the test equipment with most charging stations from different manufacturers and will accelerate the market ramp-up of electromobility.
CITE THIS POSTER
Include:
Blaz, M., Mohns, E., Leicht, C., & Schmidt, M.. (2025). Efficient verification of high-power DC charging stations with a PTB Phantom Power Test Setup. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/DQSX4350