ABSTRACT
Introduction
In 2025 it will be 130 years since the discovery of X rays by W.C Röentgen. This discovery has been of benefit to humankind contributing to their health and safety. The X rays are used in medical imaging and radiotherapy. Since early days, the medical imaging and radiotherapy modalities have evolved tremendously.
The purpose of this work is to provide an overview of developments in X ray dosimetry and related IAEA efforts towards harmonizing dosimetry methods and practices and the possible gaps that need to be addressed to ensure consistency in dosimetry for X rays.
Current challenges
As much as these developments have brought much needed solutions in health, they also have brought challenges in measurements and measurement traceability. This created opportunities for further development of detectors used for dosimetry, as well as dosimetry methods and protocols used to assess dose delivered to the patient. As the detector technology progressed the traceability system remained.
While interaction of radiation with matter has been well understood and traceability has been resolved for some of the radiation therapy applications, it has not been resolved for diagnostic radiology. The rapid development of measuring instruments and their wide availability, comes with challenges for the secondary standards dosimetry laboratories (SSDLs) as they must calibrate these wide range of instruments in conditions very close to where they will be used, in terms of irradiation geometry and radiation qualities used. Whereas the traceability received by the SSDL’s from the primary standards laboratories does not necessarily resemble those at the end user. In parallel, the dosimetry quantities and units evolved, e.g. resulting in realization of the unit of air kerma at standard dosimetry laboratories, which is used as basis for diverse application specific quantities measured in hospitals. Users may be using pulsed rather than constant beams, or different geometries that might affect the response of some equipment.
For diagnostic radiology there are various vendors supplying X ray machines and the machine characteristics vary from vendor to vendor including the beam qualities. It is impossible for calibration laboratories to establish all the radiation beam qualities and calibration methods as close as possible to those used in clinical conditions, even just considering only the national needs.
IAEA efforts
The IAEA is currently running a co-ordinated research project to evaluate the Dosimetry Needs and Practices for the Update of the Code of Practice for Dosimetry in Diagnostic Radiology (TRS-457). The participants are researchers from primary and secondary standards laboratories, members of the IAEA/WHO SSDL Network, together with medical physicists. Testing of the detectors is being performed at laboratories and clinical beams. From some of the data the instruments that are mostly used in the clinics are showing dependencies on beam qualities. This presents an opportunity in whether the standards laboratories need to introduce different beam qualities for diagnostic radiology capabilities, set up calibration using pulsed beams and organize comparisons to cover this range.
Conclusion
There are opportunities for dosimetry laboratories to reconsider the calibration capabilities in support of diagnostic radiology.
CITE THIS POSTER
Include:
Msimang, Z., Carrara, M., & Ciraj Bjelac, O.. (2025). Evolution of X ray dosimetry for medical applications and challenges in developing the dosimetry standards. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/GKKD5701
Msimang, Zakithi, et al.. “Evolution of X ray dosimetry for medical applications and challenges in developing the dosimetry standards.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/GKKD5701
Msimang, Zakithi, Mauro Carrara, Olivera Ciraj Bjelac. 2025. “Evolution of X ray dosimetry for medical applications and challenges in developing the dosimetry standards.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/GKKD5701
@inproceedings{msimang2025evolution_of_x_ray_d,
author = {Msimang, Zakithi and Carrara, Mauro and Ciraj Bjelac, Olivera},
title = {Evolution of X ray dosimetry for medical applications and challenges in developing the dosimetry standards},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/GKKD5701},
url = {https://thebipm150.org/poster-page/10eugq8},
}
TY - CONF
AU - Msimang, Zakithi
AU - Carrara, Mauro
AU - Ciraj Bjelac, Olivera
TI - Evolution of X ray dosimetry for medical applications and challenges in developing the dosimetry standards
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/GKKD5701
UR - https://thebipm150.org/poster-page/10eugq8
ER -