Reference measurement procedures for cell number concentration

AUTHORS
Andreas Kummrow

Wissenschaftlicher Angestellter, Physikalisch-Technische Bundesanstalt (PTB), Germany

Yuki Kuruma

Senior researcher, National Metrology Institute of Japan (NMIJ) / National Institute of Advanced Industrial Science and Technology (AIST), Japan

Ji Youn Lee

Principal Research Scientist, Korea Research Institute of Standards and Science (KRISS), Republic of Korea

Hiromu Sakurai

Group leader, National Metrology Institute of Japan (NMIJ) / National Institute of Advanced Industrial Science and Technology (AIST), Japan

Martin Hussels

WOR, Physikalisch-Technische Bundesanstalt (PTB), Germany

Martin Kammel

Wissenschaftlicher Angestellter, Physikalisch-Technische Bundesanstalt (PTB), Germany

Shin-ichiro Fujii

Senior researcher, National Metrology Institute of Japan (NMIJ) / National Institute of Advanced Industrial Science and Technology (AIST), Japan

6
Views
3
Downloads
MEDIA
Download PDF
DETAILS
Theme 3. Health and Life Sciences
Conference 150th anniversary of the Metre Convention — From Units to the Universe
Year 2025
Location Palais des congrès de Versailles, Versailles, France
Publisher Bureau International des Poids et Mesures (BIPM)
Language EN
ABSTRACT
Measurements of cell concentration are key for many medical decisions and are among the most frequently requested diagnostic tests. Today, these measurements are generally carried out using variants of flow cytometry. Accurate determination of cell counts is possible by applying appropriate protocols to identify the respective target cells. Corrections for coincidence losses, a common challenge in such measurements, can be addressed through dead time measurements in detection electronics or by applying a dilution series approach. These aspects can be covered already by commercial instruments. Particularly for blood cell counting, the International Council for Standardization in Haematology (ICSH) has published a set of methods to harmonize measurements for selected analytes. These methods, however, do not aim to provide traceability to SI units. The challenge on the route to standardization of cell number concentration measurements is to achieve traceable quantification of the sample volume or sample mass in which the cells are counted. This poster describes three technical implementations for volume measurement in flow cytometry, enabling SI-traceable measurement of cell (or particle) concentration [1,2,3]. The uncertainty for volume measurement in these systems can be around 1%, or lower thus offering high accuracy for measurements of cell concentrations. Interlaboratory comparisons to validate the performance of reference methods require suitable reference materials. Past CCQM pilot studies have already aimed at measuring the concentration of important cell types, i.e. CD4 positive T lymphocytes (P102) and CD34 positive hematopoietic stem cells (P165). The limited stability of cells in suspension makes it difficult to create a homogenous reference material. To overcome this barrier, the ongoing CCQM CAWG pilot study P222 explores the use of plastic beads as stable surrogates for cells. One of the reference instruments described in this poster is already listed in the JCTLM database as reference method for counting erythrocytes (C16RMP1) and platelets (C3RMMP34, C3RMMP35). Technical challenges to extend the application of reference methods to other analytes of cell counting will be discussed.
[1] S. Reitz et al. Meas. Sci. Technol. 21 (2010) 074006.
[2] Y. Kuruma et. al. Metrologia 58 (2021) 045007.
[3] Shin et al. Anal. Bioanal. Chem. 416 (2024) 4481-4490
CITE THIS POSTER
Include:
Kummrow, A., Kuruma, Y., Lee, J. Y., Sakurai, H., Hussels, M., Kammel, M., & Fujii, S.. (2025). Reference measurement procedures for cell number concentration. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/RQHD9739