Conference150th anniversary of the Metre Convention — From Units to the Universe
Year2025
LocationPalais des congrès de Versailles, Versailles, France
PublisherBureau International des Poids et Mesures (BIPM)
LanguageEN
ABSTRACT
Measurements of cell concentration are key for many medical decisions and are among the most frequently requested diagnostic tests. Today, these measurements are generally carried out using variants of flow cytometry. Accurate determination of cell counts is possible by applying appropriate protocols to identify the respective target cells. Corrections for coincidence losses, a common challenge in such measurements, can be addressed through dead time measurements in detection electronics or by applying a dilution series approach. These aspects can be covered already by commercial instruments. Particularly for blood cell counting, the International Council for Standardization in Haematology (ICSH) has published a set of methods to harmonize measurements for selected analytes. These methods, however, do not aim to provide traceability to SI units. The challenge on the route to standardization of cell number concentration measurements is to achieve traceable quantification of the sample volume or sample mass in which the cells are counted. This poster describes three technical implementations for volume measurement in flow cytometry, enabling SI-traceable measurement of cell (or particle) concentration [1,2,3]. The uncertainty for volume measurement in these systems can be around 1%, or lower thus offering high accuracy for measurements of cell concentrations. Interlaboratory comparisons to validate the performance of reference methods require suitable reference materials. Past CCQM pilot studies have already aimed at measuring the concentration of important cell types, i.e. CD4 positive T lymphocytes (P102) and CD34 positive hematopoietic stem cells (P165). The limited stability of cells in suspension makes it difficult to create a homogenous reference material. To overcome this barrier, the ongoing CCQM CAWG pilot study P222 explores the use of plastic beads as stable surrogates for cells. One of the reference instruments described in this poster is already listed in the JCTLM database as reference method for counting erythrocytes (C16RMP1) and platelets (C3RMMP34, C3RMMP35). Technical challenges to extend the application of reference methods to other analytes of cell counting will be discussed.
[1] S. Reitz et al. Meas. Sci. Technol. 21 (2010) 074006.
[2] Y. Kuruma et. al. Metrologia 58 (2021) 045007.
[3] Shin et al. Anal. Bioanal. Chem. 416 (2024) 4481-4490
CITE THIS POSTER
Include:
Kummrow, A., Kuruma, Y., Lee, J. Y., Sakurai, H., Hussels, M., Kammel, M., & Fujii, S.. (2025). Reference measurement procedures for cell number concentration. 150th anniversary of the Metre Convention — From Units to the Universe. Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/RQHD9739
Kummrow, Andreas, et al.. “Reference measurement procedures for cell number concentration.”. 150th anniversary of the Metre Convention — From Units to the Universe, 2025, Palais des congrès de Versailles, Versailles, France, Bureau International des Poids et Mesures (BIPM). DOI: 10.59161/RQHD9739
Kummrow, Andreas, et al.. 2025. “Reference measurement procedures for cell number concentration.”. 150th anniversary of the Metre Convention — From Units to the Universe, Palais des congrès de Versailles, Versailles, France. Bureau International des Poids et Mesures (BIPM). https://doi.org/10.59161/RQHD9739
@inproceedings{kummrow2025reference_measuremen,
author = {Kummrow, Andreas and Kuruma, Yuki and Lee, Ji Youn and Sakurai, Hiromu and Hussels, Martin and Kammel, Martin and Fujii, Shin-ichiro},
title = {Reference measurement procedures for cell number concentration},
booktitle = {150th anniversary of the Metre Convention — From Units to the Universe},
year = {2025},
address = {Palais des congrès de Versailles, Versailles, France},
publisher = {Bureau International des Poids et Mesures (BIPM)},
doi = {10.59161/RQHD9739},
url = {https://thebipm150.org/poster-page/10euhwe},
}
TY - CONF
AU - Kummrow, Andreas
AU - Kuruma, Yuki
AU - Lee, Ji Youn
AU - Sakurai, Hiromu
AU - Hussels, Martin
AU - Kammel, Martin
AU - Fujii, Shin-ichiro
TI - Reference measurement procedures for cell number concentration
T2 - 150th anniversary of the Metre Convention — From Units to the Universe
PB - Bureau International des Poids et Mesures (BIPM)
PY - 2025
CY - Palais des congrès de Versailles, Versailles, France
DO - 10.59161/RQHD9739
UR - https://thebipm150.org/poster-page/10euhwe
ER -